Conventional User-Friendly Evacuation Fire Alarm Control Panel System

Conventional User-Friendly Evacuation Fire Alarm Control Panel System

Conventional User-Friendly Evacuation Fire Alarm Control Panel System Model: AW-CFP2166-8 For more information, pls chec
SHARE

Description

Basic Info
Model NO. AW-CFP2166-8
Transmission Mode Cable
Alarm Volume (within 1m) ≥110dB
Receive Frequency 433.92MHz
Optional Zones 1-32
Power Supply 240VAC
Backup Lead-Acid Battery 24VDC
Optional Housing Color Red/Grey/White/Black
Fault Alert LED Indicator
Alarm Notifier LCD Display
Zone′s Capacity Maximumly Supports 20PCS
Warranty 12months
Supply Type R&D Manufacturer
OEM & ODM Service Available
Transport Package EPE Inside, Carton Outside
Specification LPCB/UL/CE/ISO
Trademark Asenware
Origin Guangdong, China
HS Code 853110000
Production Capacity 10, 000PCS/Year
Product Description
Conventional User-Friendly Evacuation Fire Alarm Control Panel System
Model: AW-CFP2166-8

For more information, pls check our website: asenware.en.made-in-china.com

Description

1. AW-CFP2166-16 conventional fire alarm panel is designed based on EN54 part 2 & 4 standard.
2. Adopted modularized design, flexible extendable capacity.
3. Two-level control mode by a lock
4.27VDC power supply output.
5. FIRE PROTECTION, FIRE ROUTING and FAULT signal output, the output can be configured to dry relay type or wet sources type.
6.2 channel general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. SILENCE button to stop BUZZER and SOUNDERS.
11. EVACUATE button to start a manual fire alarm immediately.
12. TEST button to test all LEDs orderly.
13. Low-battery protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
14. Optional GSM module is available for fire alarm by SMS.

Conventional User-Friendly Evacuation Fire Alarm Control Panel System

Conventional User-Friendly Evacuation Fire Alarm Control Panel System

 

Features

1. Panel is designed based on EN54 part 2 &4 standard
2. It is modularized design, the panel can expand from 1 zone to 32 zone easily
3. It has 2 level control mode by a lock, 24VDC power supply output, 2 general sounders output
4. Eache zone has 1circuit detectors input and can be disable by a button
5. It has FIRE and FAULT signal output, RESET button to reset the panel, SILENCE button to stop BUZZER
and SOUNDERS, EVACUATE button to start a manual fire alarm immediately
6. It has an optional GSM module for fire alarm by SMS
7. It is economic, user-friendly and easy maintenance

Parameters
ITEM1Zone panel2Zone panel4-8 Zone panel12-32 Zone panel
Model No.AW-CFP2166-01AW-CFP2166-02AW-CFP2166-04-8AW-CFP2166-12-32
Power specification
Mains supply voltage110VAC or 240VAC
Internal power supply27.2VDC
Total output current limited500mA @ 240VAC500mA @ 240VAC3A @ 240VAC3A @ 240VAC
Main supply monitor for faultYes
Battery protection for low voltageYes
Batteries (default configuration)12V2AH*2
Detector circuit specification
Number of circuit124-164-32
Line fault monitor for open circuitYes
Line fault monitor for short circuitYes
Line fault monitor for detector removalYes, if End of Line Monitor Unit fitted in place of End of Line Resistor
End of Line device6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Detector continuity diodesSilicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)
Call point resistor value470 to 680 Ω, 0.225 or 0.5 watt
Maximum number of smoke/heat detectors per zone20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.
Maximum number of manual call points per zoneNo limit
Sounder circuit specification
Number of general circuits2
End of line resistor value6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Line fault monitor for open circuitYes
Line fault monitor for short circuitYes
Outputs fused AT400mA
Maximum number of bells @ 20mA of each sounder output20
Fuses
Battery fuse1.5A F 20mm
Sounder outputs500mA F 20mm
Fire and fault output
Output typeNC and NO relay
Maximum current100mA
Connection block
Largest acceptable conductor size2.5mm2
Smallest acceptable conductor size0.75mm2
Size and weight

Dimensions(mm)272*200*70mm320*231*90mm395X502X124362X565X124
Weight (without batteries)4kg5kg7kg8kg
Weight (with batteries)5.8kg6.8kg9.6kg12.5kg

Company Information

Asenware,manufacturer of fire alarm and fire suppression system since 2005.
Our headquarter is in London, UK, with factory Shenzhen, China.

We keep our best service for our customers, and have a rich experienced engineer team to design and install
for overseas project.

Product range

Addressable fire alarm system
Conventional fire alarm system (2166 series)
FM200 gas suppression system (2159 series)
Fire pump
Fire hose/ hose reel and cabinet
ABC powder/ CO2 fire extinguisher
Emergency light system

Conventional User-Friendly Evacuation Fire Alarm Control Panel System

Conventional User-Friendly Evacuation Fire Alarm Control Panel System

Conventional User-Friendly Evacuation Fire Alarm Control Panel System


Name Card

 

Our Contact